Category : Article

article id 5176, category Article
J. Lappi, A. Kotisaari, H. Smolander. (1983). Height relascope for regeneration surveys. Silva Fennica vol. 17 no. 1 article id 5176. https://doi.org/10.14214/sf.a15091
Keywords: sampling; forest mensuration; seedling stands; measuring instruments; regeneratoin surveys; seedling height; relascope
Abstract | View details | Full text in PDF | Author Info

The choice of sampling method is of prime importance when seeking relevant information about the height distribution and spatial arrangement of seedlings in the regeneration surveys. It is suggested that the size of sampling plots should depend on the height of the seedlings. Tall seedlings should be sampled from a larger area than short ones since tall seedlings are more important for the future development of the stand. We suggest principles for a technical development task to construct a device which is easy to use in practical regeneration surveys and by which sampling can be made proportional to plant height or any desired function of height.

The PDF includes a summary in Finnish.

  • Lappi, E-mail: jl@mm.unknown (email)
  • Kotisaari, E-mail: ak@mm.unknown
  • Smolander, E-mail: hs@mm.unknown
article id 5012, category Article
Jyrki Hari, Pertti Hari, Markku Kanninen. (1978). An electronic auxanometer for field use. Silva Fennica vol. 12 no. 4 article id 5012. https://doi.org/10.14214/sf.a14866
Keywords: diameter; diameter growth; measuring instruments
Abstract | View details | Full text in PDF | Author Info

This paper describes the design and functioning of an electronic auxanometer designed for field use, and some results obtained with it. The changes in stem radius are monitored with a micrometer screw turned by an electirc motor. A potentiometer transforms the position of the screw into an electronic signal, which is recorded. The accuracy of the device is approximately 1–2 μm. Field experiments with the auxanometer are described and discussed. The accuracy of the device was found to be sufficient for measuring hourly changes in stem radius.

The PDF includes a summary in Finnish.

  • Hari, E-mail: jh@mm.unknown (email)
  • Hari, E-mail: ph@mm.unknown
  • Kanninen, E-mail: mk@mm.unknown

Register
Click this link to register to Silva Fennica.
Log in
If you are a registered user, log in to save your selected articles for later access.
Contents alert
Sign up to receive alerts of new content
Your selected articles