Current issue: 58(2)

Under compilation: 58(3)

Scopus CiteScore 2021: 2.8
Scopus ranking of open access forestry journals: 8th
PlanS compliant
Select issue
Silva Fennica 1926-1997
1990-1997
1980-1989
1970-1979
1960-1969
Acta Forestalia Fennica
1953-1968
1933-1952
1913-1932

Articles containing the keyword 'Bland-Altman plot'

Category : Research article

article id 23021, category Research article
Virpi Stenman, Annika Kangas, Markus Holopainen. (2023). Upper stem diameter and volume prediction strategies in the National Forest Inventory of Finland. Silva Fennica vol. 57 no. 3 article id 23021. https://doi.org/10.14214/sf.23021
Keywords: forest inventory; measurement errors; accuracy; Bland-Altman plot
Highlights: National Forest Inventory specific methods were applied with a number of measurement instruments, including a laser-based dendrometer, to collect tree stem diameter measurements; Bland-Altman plots and measurement error variances were used to determine measurement precision and accuracy; The laser-based dendrometer did not perform better than the other instruments in the study.
Abstract | Full text in HTML | Full text in PDF | Author Info
In forest inventories, field data are needed for the prediction of tree volumes. However, gathering field data requires resources, such as labour, equipment, and data management operations. This means that time and budget, as well as quality, must be carefully considered when National Forest Inventory (NFI) field measurement activities are planned. Therefore, the development of cost efficient, simple, safe and reliable measurement methods and tools are of great interest. To date, upper stem diameter (d6), which provides a more reliable estimation of tree stem volume, has typically been measured with a parabolic calliper. In this study, the performance of the Criterion laser-based dendrometer was examined for d6 measurements. A total of 326 sample trees were measured multiple times with three different measurement instruments. These instruments were used to measure diameter at breast height (dbh) as well as d6 measurements. Bland-Altman plots and measurement error variances were used to determine measurement instrument reliability. For all trees, the standard deviation for the laser based dendrometer was 18.73 mm at dbh and 15.36 mm for the d6 measurements. When the performance of Criterion was analysed with reference to the mean value of repeated measurements, the standard deviation in the dbh measurements was 12.21 mm, and 8.88 mm in the d6 measurements.
  • Stenman, University of Helsinki, Department of Forest Resource Management, P.O. Box 27, FI-00014 University of Helsinki, Finland ORCID https://orcid.org/0000-0003-1176-7840 E-mail: virpi.stenman@helsinki.fi (email)
  • Kangas, Natural Resources Institute Finland (Luke), Bio­economy and Environment, P.O. Box 68, FI-80101 Joensuu, Finland ORCID https://orcid.org/0000-0002-8637-5668 E-mail: annika.kangas@luke.fi
  • Holopainen, University of Helsinki, Department of Forest Resource Management, P.O. Box 27, FI-00014 University of Helsinki, Finland E-mail: markus.holopainen@helsinki.fi

Register
Click this link to register to Silva Fennica.
Log in
If you are a registered user, log in to save your selected articles for later access.
Contents alert
Sign up to receive alerts of new content
Your selected articles